CVE
CVE
added 2021/07/14 3:15 p.m.82 views

CVE-2021-22779

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack R...

9.1CVSS9AI score0.00101EPSS
CVE
CVE
added 2022/03/09 11:15 p.m.75 views

CVE-2022-24323

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoS...

5.9CVSS5.7AI score0.00221EPSS
CVE
CVE
added 2023/01/31 6:15 a.m.73 views

CVE-2022-45789

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Version...

9.8CVSS9.3AI score0.00057EPSS
CVE
CVE
added 2022/04/14 1:15 p.m.69 views

CVE-2022-26507

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CV...

9.8CVSS9AI score0.02994EPSS
CVE
CVE
added 2022/04/13 4:15 p.m.67 views

CVE-2021-22797

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the en...

9.3CVSS7.7AI score0.00452EPSS
CVE
CVE
added 2022/09/12 6:15 p.m.64 views

CVE-2022-37300

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStr...

9.8CVSS9.1AI score0.00288EPSS
CVE
CVE
added 2023/01/30 1:15 p.m.63 views

CVE-2022-45788

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All V...

9.8CVSS9.5AI score0.00293EPSS
CVE
CVE
added 2021/07/14 3:15 p.m.52 views

CVE-2021-22782

Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versi...

5.5CVSS5.3AI score0.00016EPSS
CVE
CVE
added 2021/07/14 3:15 p.m.50 views

CVE-2021-22778

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versi...

7.1CVSS6.7AI score0.00045EPSS
CVE
CVE
added 2021/07/14 3:15 p.m.47 views

CVE-2021-22781

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versi...

5.5CVSS5.5AI score0.00052EPSS
CVE
CVE
added 2021/07/14 3:15 p.m.44 views

CVE-2021-22780

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versi...

7.1CVSS6.8AI score0.00054EPSS
CVE
CVE
added 2024/02/14 5:15 p.m.36 views

CVE-2023-6408

CWE-924: Improper Enforcement of Message Integrity During Transmission in aCommunication Channel vulnerability exists that could cause a denial of service and loss ofconfidentiality, integrity of controllers when conducting a Man in the Middle attack.

8.1CVSS7.8AI score0.00157EPSS
CVE
CVE
added 2024/02/14 5:15 p.m.35 views

CVE-2023-6409

CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorizedaccess to a project file protected with application password when opening the file withEcoStruxure Control Expert.

7.7CVSS7.5AI score0.00062EPSS
CVE
CVE
added 2024/02/14 5:15 p.m.26 views

CVE-2023-27975

CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorizedaccess to the project file in EcoStruxure Control Expert when a local user tampers with thememory of the engineering workstation.

7.1CVSS6.7AI score0.00074EPSS